SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.D I R E C T V E N T F I R E P L A C EB Y :
10Maintenance And ServiceCLEANING DECORATIVE SURFACES:Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has
11FUEL CONVERSION:Maintenance And ServiceTO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYPlease read and understand these instructions before instal
12Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 11), rotate it counter-
13Maintenance And ServiceRed o-ringis not visibleRed o-ringis visibleLPG Configuration8. Reinstall the burner, brick panels, log set, embers, and gla
Initial InstallationQUALIFIED INSTALLERS ONLYINTRODUCTION:This section of the owner’s manual is for the use of qualied technicians only. Firepla
Mount the two framing mount brackets on each side and secure the replace to framing with screws or nails (refer to Figure 16). The bracket
3"(76mm)12"(305mm)6"(152mm)14"(356mm)Top of unit3” (76mm) mantle10" (254mm) mantleCombustible front face3/4" (19mm) faci
171 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National
Initial InstallationQUALIFIED INSTALLERS ONLY18Figure 25: Wire Spacers.it to the inner wall frame using four (4) 1” wood screws.
Flue Pipe AdaptorWall FramingWall ThimbleFire StopExhaust 4" Flex PipeCombusion Air 65/8" Flex PipeWire SpacersHorizontal Vent Termination19
2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Di
21Initial InstallationQUALIFIED INSTALLERS ONLYVENTING:This replace has been tested and certied for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS”
VentRestrictorPosition20’(6.10m)25’(7.62m)30’(9.14m)32’(9.75m)413/4”(106cm) fromfloor0’(0m)0’(0m)15’(4.57m)15’(4.57m)17’(5.18m)5’(1.52m)5’(1.52m)10’(3
23Wall framingHorizontal wallterminationWall thimblefire stopExhaustflex pipeCombustion airouter pipeElbowInitial InstallationQUALIFIED INSTALLERS ONL
24Initial InstallationQUALIFIED INSTALLERS ONLYStep 3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10 inch (25.4 c
25Initial InstallationQUALIFIED INSTALLERS ONLYSTEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole shoul
NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (9
Initial InstallationQUALIFIED INSTALLERS ONLYINSTALLATION OF ELECTRICAL WIRING FOR THE OPTIONAL FAN KIT:Figure 39. Wiring Diagram For Gas Valve.COOL/
28Initial InstallationGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to
29Figure 41: This is how the re box looks with only the grate and Optional Brick Panels in place. The burner has three (3) locator pins for
Table of Contents3Safety Precautions...2Table of
Secondary InstallationFigure 44: The right log has two (2) holes in it that will rest over the two (2) locator pins pointed out in Figure 43.Figure 4
31Secondary InstallationFigure 47: Once the logs are in place the embers can be placed onto and around the burner to create a realistic look. B
32Secondary InstallationOPTIONAL CERAMIC BRICK PANEL INSTALLATION:BaffleLedgeTurn off the gas control knob and allow the unit to cool.Please ensure th
Secondary InstallationQUALIFIED INSTALLERS ONLYOPTIONAL FAN KIT INSTALLATION:The optional fan is thermostatically controlled and it will not
Figure 56. Install Fan Control Box. Figure 57. Plug In Fan Kit.34Secondary InstallationInstallation of Kit:1. Ensure the appliance is turned off and c
Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas c
Parts ListReference NumberPart Description Part Number1 120°F Ceramic Fan Temperature Sensor EC-0012 Thermocouple EC-0092 Spark Electrode with Ignitor
Parts List - OptionsReference NumberPart Description Part Number17 Brick Panels (set of 3) 50-92618 Louvre Set - Brushed Antique Copper (set of 2) 50-
38Parts Diagram
WarrantySherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a pe
4DIRECT VENT ONLY: This type is identied by the prex DV. This appliance draws all of its air for combustion from outside the dwelling, through a spe
40Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________
Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTI
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several t
8Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingE) Turn on all electrical power to the uni
Maintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system is clean and working proper