Enviro Kodiak 1200 Insert Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Enviro Kodiak 1200 Insert. Enviro Kodiak 1200 Insert User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 55
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Kodiak
Wood Stove
Models: 1200 & 1700 Insert and 1200 & 1700 Fireplace Freestanding
Tested &
Listed By
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc,
C
O-
T L
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD
BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Contact your local building or re ofcials, or the authority having jurisdiction
about restrictions and installation inspection requirements in your area.
This heater meets the U. S. Environmental Protection Agencies
emission limits for wood heaters sold after July 1st, 1990.
Under specic conditions this heater has been shown to deliver
heat at rates ranging from 11,479 to 34,196 BTU per hour for
the 1200 and from 9,425 to 31,780 BTU per hour for the 1700.
50-1040
INSTALLER: Leave this manual with the wood stove.
CONSUMER: Retain this manual for future reference.
Vista de página 0
1 2 3 4 5 6 ... 54 55

Resumo do Conteúdo

Página 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Página 2 - Table of Contents

Operating InstructionsHOW IT WORKS:1/2" Ceramic baffle;reflects heat downto burn up smoke.Secondary air tubes;creates a secondaryburn on the part

Página 3 - Safety Precautions

11Specifications1200 SPECIFICATIONS:Model 1200 Freestanding 1200 InsertFlat Top Step TopWidth x Depth 25” x 22 7/16” (635 mm x 570 mm)27” x 21” (70

Página 4

Specifications1700 SPECIFICATIONS:Model 1700 Freestanding 1700 InsertFlat Top Step TopWidth x Depth 25” x 26 15/16” (635 mm x 684 mm)27” x 26” (705

Página 5

13SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshi

Página 6

14SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshi

Página 7

SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Table 9: 1200 Freestanding C

Página 8

SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Table 10: 1700 Freestanding

Página 9

17SpecificationsDIMENSIONS - 1200 INSERT:3/16"(5mm)183/8"(467mm)Regular Surround2715/16" (709mm)OversizedSurround333/16"(709mm)191

Página 10 - Operating Instructions

SpecificationsDIMENSIONS - 1200 INSERT:337/8" (860mm)461/8" (1171mm)273/4" (705mm)3/16"(5mm)183/8"(467mm)Regular Surround2715

Página 11 - Specifications

19SpecificationsDIMENSIONS - 1200 FREESTANDING:25"(635mm)61/16"(153mm)915/16"(252mm)281/4"(718mm)2915/16"(760mm)301/4"(7

Página 12

Table of Contents2Safety Precautions...3Operating Instructi

Página 13

SpecificationsDIMENSIONS - 1700 FREESTANDING:2615/16"(684mm)915/16"(252mm)157/8"(403mm)25"(635mm)193/8"(492mm)61/16"(153

Página 14

21SpecificationsFREESTANDING SIDE DIMENSIONS FOR FAN KIT:   

Página 15

InstallationPlease read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow these

Página 16

23• Place the unit on the pallet on its back.• Attach pedestal spacer to bottom of the unit, using the supplied screws.• Attach the air channel b

Página 17 - /8" (683mm)

InstallationHEARTH PROTECTION EXAMPLES:Table 11: Examples of Hearth Pad Sizing Using Clearances From Tables 9 &10 (refer to Figures 19 & 20).C

Página 18

Installation25Door OpeningIAGCUSA 16" (406mm)CND 18" (457mm)EUSA 6"(152mm)CND 8"(203mm)USA 6" (152mm)CND 8" (203mm)H DFB

Página 19

26Table 13: Examples of Corner Installation Using Clearances From Tables 9 &10 (refer to Figures 20 & 21).(K) Front of Hearth Pad to Corner (

Página 20

InstallationOUTSIDE AIR KIT:It is mandatory to use outside air for installations in mobile homes.A 4” (10.2 cm) fresh air adaptor kit is avai

Página 21

InstallationCHIMNEY INSTALLATION THROUGH WALL:Here are four (4) methods of combustible wall chimney connector pass-throughs. Information was provided

Página 22 - Installation

29InstallationINSTALLATION OF A LISTED, FACTORY BUILT CHIMNEY - FREESTANDING:This is a generic set of instructions; always follow the chimney manufact

Página 23

3Safety PrecautionsFOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:● Please read this

Página 24

InstallationHearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorChimneyconnectorCeilingInsulated chimneyRoof flashing

Página 25

31InstallationMASONRY CHIMNEY INSTALLATION - FREESTANDING:DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.A non-combustible oo

Página 26

Figure 32: Freestanding Installation into existing replace.Unless you are experienced, we recommend installation by your dealer or a professional ins

Página 27

33At least3 feet (914 mm)HearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorDouble wall pipeCeiling supportCeilingSp

Página 28

InstallationMASONRY FIREPLACE INSTALLATION - INSERT:Unless you are experienced, we recommend installation by your dealer or a professional installer.I

Página 29

35The ue collar is removable for installations into replaces with low openings. a) Remove the rst two (2) front secondary air tube

Página 30

InstallationFigure 38: Attaching removable ue.Figure 39: Leveling leg.SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:Before starting this

Página 31

37InstallationINSTALLATION USING A BLOCK-OFF PLATE FOR USA ONLY - INSERT:If this unit is to be installed into a masonry replace or a zero-clearance 

Página 32

Installation5. Mount the block-off plate using masonry screws in a masonry replace and sheet metal screws on a zero-clearance replac

Página 33

39InstallationMODEL 1200 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacin

Página 34

Operating InstructionsFIRST STARTWhen rst installed, the chimney, rebricks and steel are cold and it usually takes several hours on a fairly high bu

Página 35

InstallationMODEL 1700 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Página 36

41InstallationDOOR INSTALLATION:Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distr

Página 37

CERAMIC BAFFLE INSTALLATION:1. Remove the front secondary air tube by placing a screwdriver (any style except at head) into one of Left CeramicBaffle

Página 38

43The fan kit is pre-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan as

Página 39

Figure 55: Changing decorative plate.InstallationREMOVAL OF THE SHROUDS - INSERT:ABB1. If the surround panel is installed, remove it by lifting the p

Página 40

45InstallationINSTALLATION OF THE SURROUND PANEL - INSERT:Figure 58: Screw to hold the trim against the sur-round.Figure 56: Corner brackets for trim.

Página 41

Parts ListReferance # Description Part #1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 FPI Fan Controller - 115V EC-0392 Fan Controller Knob EC

Página 42

47Parts ListReferance # Description Part #24 Pumice Bricks - 4” X 4” (114mm x 114mm) 50-110625 1200 & 1700 Ash Dump Cover 50-112026 Door Handle

Página 43

Parts Diagram - Freestanding3130343529283332151719184625444277926143161721202322244345816Kodiak - Freestanding ComponentsApril 200748

Página 44 - Figure 55: Changing

49Parts Diagram - Pedestals & Legs111310124139405383637Kodiak - Pedestal and Leg Kit ComponentsMay 2006

Página 45 - Figure 58: Screw to hold

REPLACING THE GLASS:Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the re is burning, do

Página 46 - Parts List

Parts Diagram - Fireplace Insert4915535447850485152544232Kodiak - Fireplace Insert ComponentsApril 2007Common parts are shown inParts Diagram - Freest

Página 47

51WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to

Página 48 - Parts Diagram - Freestanding

Warranty5. If Sherwood Industries Ltd. determines that the stove needs to be returned to Sherwood Industries Ltd. for repair, the customer has the res

Página 49 - May 2006

53Warranty11. The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or spillage caused by envir

Página 50 - Common parts are shown in

Warranty24. Sherwood Industries Ltd. will not cover the cost of the removal or re-installation of the stove, hearth, facing, mantels, venting or othe

Página 51 - Warranty

55Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Página 52

6Operating InstructionsMAINTENANCE:At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top bafe

Página 53

7Operating Instructionsc) DO NOT OVERFIRE. If the heater or chimney connector glows, you are overring.d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEAT

Página 54

8Operating Instructionslength for the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the lo

Página 55 - Installation Data Sheet

9Operating Instructionsa) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compe

Comentários a estes Manuais

Sem comentários